Zero-voltage switching. Current range: 15 A to 120A
• Input control from logic signal
• Switching at voltage zero crossing
• Versions with TRIAC and with double SCR in antiparallel
• LED power on indicator •MOV protections (varistor)
• Fastening to DIN bar (standard); fastening to panel (optional)







Zero-voltage switching. Current range: 25A to 40A, diagnostics and load interrupt alarm
• AC power solid state relays with logic signal control
• Switching at voltage zero crossing
• Built-in heatsink •Rated current: 25Arms, 40Arms
• Non-repetitive voltage: 1200 Vp
• Rated voltage: up to 530VCArms
• Input control range: 5…30 Vdc
• Optical isolation: 4000Vrms (input/output)
• Built-in HB diagnostics (partial heater break, junction in short circuit)
• Overheat protection (optional)
• 2-color control signal LED in input/alarm state
• On-board MOV (varistor)
• DIN rail or panel mounting (optional)
Zero-voltage switching, optimised fast cycle time. Current range: 25A to 120A, diagnostics and load interrupt alarm
• Command input from analogue voltage or current signal or potentiometer
• Switching at voltage zero crossing
• Partialization of wave train power with dynamically optimized time cycle •Antiparallel double SCR
• 2 led for supply indication, “ON” state, 1 optional LED for load interrupt alarm
• 4000V isolation between input circuit and power output
• MOV (varistor)
• Optional monitoring of interrupted load
• DIN rail mounting (standard); Panel mounting (optional)
     
GTZ GQ GS
Zero-voltage switching. Current range: 25A to 55A
• 3-phase alternating current solid state relay with integrated hestsink
• Zero crossing switching •3-phase nominal current 3x25/40/55A
• Nominal voltage up to 600VCArms Control range:5...32Vdc
• Optoinsulation (input/output) 4000Vrms
• Integrated overvoltage suppressor
• Non-repetitive voltage up to 1200Vp
• Component selection to operate at max. declared current with ≤ 40°C temperature •DIN bar mounting with fast clip-on
• In Conformity with EN60947-4-3 and UL508
Zero-voltage switching. Current range:15A to 90A
• Alternating current solid state relay
• Zero crossing switching
• Copper/semiconductor coupling technology
• 10, 25, 50, and 90 Arms nominal current
• Non-repetitive voltage: up to 1600Vp
• Nominal Voltage: up to 600VCAms
• Control voltage : 3...32Vcc and 20...260Vac/Vcc with connector
• Isolation (input-output) 4000Vrms
• Red LED drive active signal
• Internal MOV (option)
Zero-voltage switching. Current range:15A to 120A
• Alternating current solid state relay
• Zero crossing switching
• Copper/semiconductor coupling technology
• 10, 15, 20, 25, 40, 50, 60, 90, and 120 Arms Arms nominal current
• Non-repetitive voltage: up to 1200 Vp
• Nominal Voltage: up to 530VCAms
• Input control range: 5...32 Vcc
• 4000 Vrms optoinsulation (input-output)
• Green LED, drive input signal indicator
• MOV (varistors)
GZ GD GT
Zero-voltage switching. Current range: 10A to 55A
• 3-phase alternating current solid state relay
• Zero crossing switching
• 3-phase nominal current 3x10/25/40/55A
• Nominal voltage up to 600VCArms
• Control range: 5...32Vdc
• Optoinsulation (input/output) 4000Vrms
• Integrated overvoltage suppressor
• Non-repetitive voltage up to 1200Vp
• In Conformity with EN60947-4-3 and UL508


Zero-voltage switching. Current range: 40A, diagnostics and load interrupt alarm
• AC solid state relays with logic signal control
• Switching at voltage zero crossing
• Built-in heatsink o Rated current: 25Arms, 40Arms
• Non-repetitive voltage: 1200 Vp
• Rated voltage: up to 530VCArms
• Input control range: 5…30 Vdc
• Optical isolation: 4000Vrms (input/output)
• Built-in HB diagnostics (partial heater break, junction in short circuit)
• Overheat protection (optional)
• 2-color control signal LED in input/alarm state
• On-board MOV (varistor)
Zero-voltage switching, optimised fast cycle time. Current range: 25A to 120A, diagnostics and load interrupt alarm
• Command input from analogue voltage or current signal or potentiometer.
• Switching at voltage zero crossing.
• Partialization of wave train power with dynamically optimized time cycle.
• Antiparallel double SCR
• 2 led for supply indication, “ON” state, 1 optional LED for load interrupt alarm
• 4000V isolation between input circuit and power output
• MOV (varistor) •Optional monitoring of interrupted load