SAFETY SENSORS
 
SNH-Emergency Stop Button  

Features
• For applications up to IP69K
• Tapmer-proof according to EN 418/EN ISO 13850
• Modular design
• Turn-to-reset
• Integrated illumination
• Optical indication of the switching state
• Up to PL e / Category 4 (EN ISO 13849-1)
• Up to SILcl 3(EN 62061)
SIN-Safety switch with seperated actuator and guard locking  
Features
• Suitable for locking devices in accordance with EN 14119
• Flexible use with 4 horizontal or 4 vertical actuating directions
• Integrated protection against simple bypassing
• Long service life thanks to dust- and water-proof housing and a broad operating temperature range of up to 70 °C
• Locking force 1,500 N
SMS-Safety switch with seperated actuator  
Features
• Flexible use with 2 horizontal or 2 vertical actuating directions
• Protection against simple bypassing in accordance with EN 14119 through multiple coding of the actuator
• Long service life thanks to dust- and water-proof housing and a broad operating temperature range of up to 80 °C.
• Increased extraction force up to 30 N • Easy installation with adjustment via slots and final fixing via round holes
STS-Non-contact safety switches with coding  
Features
• Individual coding for maximum manipulation protection
• Up to PL e / category 4 (EN 13849-1)
• Up to SILCL 3 (EN 62061)
• Up to 30 sensors can be cascaded
• Automatic or manual start
• LED and semiconductor output for diagnostics
• Switching distance of 8 mm / 10 mm
• Protection class IP67 / IP69K
SMA – Magnetic safety switches  
Features
• Block-shaped design
• For harsh operating conditions
• Tamper proof
• Can be used up to PL e /Category 4 (EN ISO 13849-1)
• Degree of Protection IP67
Features
• Rectangle-shaped design
• For harsh operating conditions
• Tamper proof • Can be used up to PL e /Category 4 (EN ISO 13849-1)
• Degree of Protection IP67
Features
• Round-shaped design
• For harsh operating conditions
• Tamper proof • Can be used up to PL e /Category 4 (EN ISO 13849-1)
• Degree of Protection IP67
SMI 1001 – Magnetic switch interface  
Features
• Control via a maximum of 4 two-channel sensors
• Signal output for each sensor
• Optical indication of the switching state of each sensor